Event name
Servo Drive Overheat
Meaning
The temperature of the Servo Drive radiator or power elements exceeded the specified value.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The ambient temperature of the
Servo Drive exceeded the specified
value.
Overload
Attached
None
information
Precautions/
"15" is displayed on the Servo Drive front panel and F015 is given as the AlarmCode (4001 hex)
Remarks
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Improve the ambient temperature and
the cooling conditions of the Servo
Drive.
Increase the capacities of the Servo
Drive and the motor. Or, increase the
setting of the acceleration/
deceleration time and lighten the
load.
Event code
34E10000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Check the ambient temperature of the
Servo Drive and set up the necessary
cooling conditions.
Increase the setting of the
acceleration/deceleration time and
lighten the load as much as possible.
Appendicies