Appendicies
Event name
EtherCAT Communications Warning
Meaning
An EtherCAT communications error occurred one or more times.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The EtherCAT communications cable
is disconnected or broken.
Noise
Attached
None
information
Precautions/
"B2" is displayed on the front panel of the Servo Drive.
Remarks
A-158
Source details
Observation
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Connect the EtherCAT
communications cable securely. If the
cable is broken, replace it.
Take noise countermeasures if
excessive noise is affecting the
EtherCAT communications cable.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Event code
84B00000 hex
Slave
Detection
timing
---
Log category
Not affected.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Connect the EtherCAT
communications cable securely.
Take noise countermeasures if
excessive noise is affecting the
EtherCAT communications cable.