Event name
Motor Combination Error 1
Meaning
The value set for the motor current exceeds the maximum motor capacity allowed for the Servo Drive.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The rated/maximum current of the
motor exceeds the maximum motor
capacity allowed for the Servo Drive.
Attached
None
information
Precautions/
"50" is displayed on the Servo Drive front panel and F160 is given as the AlarmCode (4001 hex).
Remarks
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Check the Motor Rated Rms Current
(3906 hex)/Motor Peak Absolute
Current (3907 hex) and correct the
set value if incorrect.
If the set value is correct, replace the
Servo Drive with one whose
maximum motor capacity is the Motor
Rated Rms Current/Motor Peak
Absolute Current or higher.
Event code
28020000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Make sure that the value set for the
Motor Rated Rms Current (3906 hex)/
Motor Peak Absolute Current
(3907 hex) is correct.
Use a Servo Drive whose maximum
motor capacity is the Motor Rated
Rms Current/Motor Peak Absolute
Current or higher.
Appendicies
Continuously
System
A-123