Wiring; Peripheral Equipment Connection Examples - Omron R88D-KN series User Manual

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

4 System Design
4-2

Wiring

This section provides information on the power supply, main circuit, and terminal blocks and other parts of the G5-series Servo Drives.
4-2-1

Peripheral Equipment Connection Examples

R88D-KN01L-ECT-L/-KN02L-ECT-L/-KN04L-ECT-L
R88D-KN01H-ECT-L/-KN02H-ECT-L/-KN04H-ECT-L/-KN08H-ECT-L/
R88D-KN10H-ECT-L/-KN15H-ECT-L (Single-phase Input)
Ground to
100 Ω or less
1MC
Regeneration
Resistor
24 VDC
User-side
control
device
Control cables
4-4
R
T
Single-phase 100 to 120 VAC, 50/60Hz: R88D-KN
Single-phase 200 to 240 VAC, 50/60Hz: R88D-KN
NFB
(*1)
Noise filter
1
2
Main circuit
E NF
power supply
3
4
OFF
ON
1MC
X
G5-Series
AC Servo Drive
CNA
L1C
L2C
CNA
L1
Reactor
L3
CNB
B1
(*3)
B3
(*4)
B2
CN1
X
3
/ALM
4
ALMCOM
X
OUTM1
(BKIR)
OUTM1
CN1
COM
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Main circuit
contactor (*1)
X
1MC
Surge suppressor
PL
Servo error display
Power cables
CNB
U
V
W
Ground to
100 Ω or less
CN4
External Encoder cables
*1. A recommended product is listed in 4-3, Wiring
Confirming to EMC Directives.
*2. Recommended relay: MY relay by OMRON (24-V)
MY2 relay by OMRON can be used because its
CN1
rated inductive load is 2 A (24 VDC).
24 VDC
*3. Models with a built-in Regeneration Resistor
1
XB
(KN04L-ECT-L, KN08H-ECT-L, KN10H-ECT-L and
(*2)
KN15H-ECT-L) have B2 and B3 shorted. When the
2
amount of regeneration is large, remove the
connection between B2 and B3 and connect a
Regeneration Resistor between B1 and B2.
*4. There is no Internal Regeneration Resistor for
KNA5L-ECT-L to KN02L-ECT-L, and KN01H-ECT-L
to KN04H-ECT-L. When the amount of regeneration
is large, connect the necessary Regeneration
Resistor between B1 and B2.
L-ECT-L
H-ECT-L
(*1)
Motor
M
S

Hide quick links:

Advertisement

Table of Contents
loading