4
Set the Damping Filter Selection (3213 hex).
Damping filters 1 to 4 can be switched according to the conditions of the machine vibration.
Set value
0
1
2
3
*1 The set value 1 and 2 are reserved for system use. Users are not allowed to set 1 and 2 for this object.
*2 The table below shows the damping filter you can switch to based on the command direction.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Up to two filters, Damping Filter 1 and Damping Filter 2, can be used simultaneously.
*1
Reserved
*1
Reserved
The damping filters are switched in the direction of the position command.
Direction of
Damping
position
filter 1
command
Positive
Enabled
Negative
Disabled
11 Adjustment Functions
Description
Damping
Damping
Damping
filter 2
filter 3
filter 4
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
*2