Event name
External Latch Input Allocation Error
Meaning
There is an error in the latch input function allocation.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The latch input was allocated to an
input signal other than IN5, IN6, or
IN7.
A latch input is assigned to an NC
signal.
The same latch input is not assigned
to the same pin in all Control Modes.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F833 is given as the AlarmCode (4001 hex).
Remarks
Event name
Overrun Limit Error
Meaning
The motor exceeded the allowable operating range set in the Overrun Limit Setting (3514 hex) with respect to the
position command input range.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The gain or mass ratio is not suitable.
The set value of the Overrun Limit
Setting (3514 hex) is too small.
Attached
None
information
Precautions/
"34" is displayed on the Servo Drive front panel and F034 is given as the AlarmCode (4001 hex).
Remarks
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Allocate the latch input to input
signals IN5, IN6, or IN7.
Assign a latch input to an NO signal.
Assign the same latch input in all
Control Modes.
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Adjust the gain (the balance between
position loop gain and velocity loop
gain) and the mass ratio.
Increase the set value of the Overrun
Limit Setting (3514 hex). Disable the
protective function if it is unnecessary.
Event code
384B0000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Allocate the latch input to input
signals IN5, IN6, or IN7.
Assign a latch input to an NO signal.
Assign the same latch input to the
same pin in all Control Modes.
Event code
384C0000 hex
Slave
Detection
timing
Error reset (after
Log category
resetting slave
errors)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Adjust the gain or mass ratio.
Increase the set value of the Overrun
Limit Setting (3514 hex). Disable the
protective function if it is unnecessary.
Appendicies
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
System
While power is
supplied to motor
System
A-137