Servo Drive Regeneration Absorption Capacity

The following table shows the regenerative energy (and amount of regeneration) that each drive can
absorb. If these values are exceeded, take the processes described above.
Servo Drive model
R88D-KN01L-ECT-L
R88D-KN02L-ECT-L
R88D-KN04L-ECT-L
R88D-KN01H-ECT-L
R88D-KN02H-ECT-L
R88D-KN04H-ECT-L
R88D-KN08H-ECT-L
R88D-KN10H-ECT-L
R88D-KN15H-ECT-L
R88D-KN20H-ECT-L
R88D-KN30H-ECT-L
R88D-KN50H-ECT-L
R88D-KN75H-ECT-L
R88D-KN150H-ECT-L
R88D-KN06F-ECT-L
R88D-KN10F-ECT-L
R88D-KN15F-ECT-L
R88D-KN20F-ECT-L
R88D-KN30F-ECT-L
R88D-KN50F-ECT-L
R88D-KN75F-ECT-L
R88D-KN150F-ECT-L
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Regenerative
energy absorbable by
built-in capacitor [J]
11
15
22
18
18
26
46
74
74
74
113
113
282
254
64
64
64
64
106
106
273
492
Internal regeneration resistor
Average amount of
regenerative energy
absorbable [W]
17
12
18
18
72
60
60
21
21
21
29
60
60
4 System Design
Allowable
minimum
regeneration
resistance []
17
17
13
34
34
34
25
25
25
10
7
5
4
4
100
100
100
40
40
29
14
14