Omron R88D-KN series User Manual page 279

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Damping Frequency 2
3216 hex
Setting range
0 to 2000
Size
2 bytes (INT16)
• Set
damping frequency
• Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
• Setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
Refer to 11-5 Damping Control on page 11-16.
Damping Filter 2 Setting
3217 hex
Setting range
0 to 1000
Size
2 bytes (INT16)
• First set
Damping
increase the setting to increase operation speed. Normally, use a setting of "0."
• The upper limit of the set value is restricted to the corresponding damping frequency or the value of
(2000 - damping frequency), whichever is the smaller.
Refer to 11-5 Damping Control on page 11-16.
Damping Frequency 3
3218 hex
Setting range
0 to 2000
Size
2 bytes (INT16)
• Set
damping frequency
• Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
• Setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
Refer to 11-5 Damping Control on page 11-16.
Damping Filter 3 Setting
3219 hex
Setting range
0 to 1000
Size
2 bytes (INT16)
• First set
Damping
increase the setting to increase operation speed. Normally, use a setting of "0."
• The upper limit of the set value is restricted to the smaller value of the corresponding damping
frequency or (2000  damping frequency).
Refer to 11-5 Damping Control on page 11-16.
Damping Frequency 4
3220 hex
Setting range
0 to 2000
Size
2 bytes (INT16)
• Set
damping frequency
• Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
• Setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
Refer to 11-5 Damping Control on page 11-16.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Unit
0.1 Hz
Access
2 to suppress vibration at the end of the load in damping control.
Unit
0.1 Hz
Access
Frequency 2 (3216 hex). Then reduce the setting if force saturation occurs or
Unit
0.1 Hz
Access
3 to suppress vibration at the end of the load in damping control.
Unit
0.1 Hz
Access
Frequency 3 (3218 hex). Then reduce the setting if force saturation occurs or
Unit
0.1 Hz
Access
4 to suppress vibration at the end of the load in damping control.
9 Servo Parameter Objects
Default setting
0
RW
PDO map
Default setting
0
RW
PDO map
Default setting
0
RW
PDO map
Default setting
0
RW
PDO map
Default setting
0
RW
PDO map
csp pp hm
Data attribute
B
Not possible.
csp pp hm
Data attribute
B
Not possible.
csp pp hm
Data attribute
B
Not possible.
csp pp hm
Data attribute
B
Not possible.
csp pp hm
Data attribute
B
Not possible.
9-21
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents