Omron R88D-KN series User Manual page 494

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Appendicies
Event code
Event name
04AA0000 hex
Main Circuit
Power
Supply
Undervoltage
(Undervoltag
e between
positive and
negative
terminals)
04AB0000 hex
Main Circuit
Power
Supply
Undervoltage
(AC Cutoff
Detected)
04AC0000 hex
Overcurrent
A-94
Meaning
Assumed cause
If the Undervoltage
• Insufficient power supply
Error Selection
capacity
(3508 hex) is set to
• The electromagnetic contactor
1, a momentary
in the main circuit power supply
power interruption
was tripped.
occurred between
• A momentary power
L1 and L3 for longer
interruption occurred.
than the value
• A Servo Drive with 3-phase
specified for the
input specifications was
Momentary Hold
operated with a single-phase
Time. The voltage
power supply.
between the
• The Servo Drive failed.
positive and
negative terminals
in the main power
supply converter
dropped below the
specified value
while the Servo was
ON.
If the Undervoltage
• Insufficient power supply
Error Selection
capacity
(3508 hex) is set to
• The electromagnetic contactor
1, a momentary
in the main circuit power supply
power interruption
was tripped.
occurred between
• A momentary power
L1 and L3 for longer
interruption occurred.
than the value
• A Servo Drive with 3-phase
specified for the
input specifications was
Momentary Hold
operated with a single-phase
Time. The voltage
power supply.
between the
• The Servo Drive failed.
positive and
negative terminals
in the main power
supply converter
dropped below the
specified value
while the Servo was
ON.
The current flowing
• A short-circuit, line-to-ground
through the
fault, contact failure, or
converter exceeded
insulation failure occurred on
the specified value.
the U, V, or W motor line.
• The Servo Drive failed.
• The relay for the dynamic brake
has been welded due to
frequent Servo ON/OFF
operations.
• Motor windings are burned out.
• The motor is not suitable for the
Servo Drive.
• The command input timing is
the same as or earlier than the
Servo ON timing.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Level
Maj
Prt
Min
Obs Info
Reference
page A-108
page A-109
page A-110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents