10 Operation
Checking the EtherCAT Communications Connectors
• The EtherCAT Communications Cables must be connected securely to the EtherCAT
Communications Connectors (ECAT IN and ECAT OUT).
Checking the Node Address Setting
Make sure that the node address is correctly set on the node address switches.
Status indicators
RUN
ERR
L/A IN
L/A OUT
Node address
switch setting
00
01 to 99
Precautions for Correct Use
Precautions for Correct Use
• Do not change the setting on the Node Address switches after the power supply has been
turned ON.
• The node address switches can be set to between 00 and 99.
The node address used over the network is determined by the value set on the Node Address
switches.
If the node address is not between 00 and 99, a Node Address Setting Error (Error No. 88.0)
will occur.

10-2-2 Turning ON the Power Supply

Turn ON the control circuit power after you conduct the pre-power-ON checking.
You may turn ON the main circuit power, but it is not a required.
10-4
ADR
x10
CN5
Connection to NJ501-100 and
CJ1W-NC281/NC481/NC881/NCF81/NC482/NC882/F82 Position Control Unit
The controller sets the node address.
The Node Address switch setting is used as the node address.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Node address switch
x1