Related Objects - Omron R88D-KN series User Manual

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

6 Basic Control Functions
The following diagram shows the control function configuration of Profile position mode.
Position demand value (6062 hex)
Following error window (6065 hex)
Max torque (6072 hex)
6-4-1

Related Objects

Index
Sub-index
6040 hex
00 hex
6060 hex
00 hex
*1
00 hex
6065 hex
6072 hex
00 hex
*2
00 hex
607A hex
607D hex
01 hex
02 hex
6081 hex
00 hex
6083 hex
00 hex
6084 hex
00 hex
6086 hex
00 hex
6041 hex
00 hex
6062 hex
00 hex
6064 hex
00 hex
606C hex
00 hex
6077 hex
00 hex
60F4 hex
00 hex
60FA hex
00 hex
60FC hex
00 hex
*1 The Following error window object can be set to between 0 and 134,217,728, or 4,294,967,295. If the object is set to
4,294,967,295, the detection of Following error will be disabled. If it is set to 0, a Following error will always occur. If the
set value is between 134,217,729 and 4,294,967,294, it is assumed that 134,217,728 is set. In this case, 134,217,728 will
be returned when the object is read.
*2 For the Servo Drive to accept commands without fail, the object value must always be retained for two communications
cycles or more.
6-12
Limit
function
Name
Access
Controlword
RW
Modes of operation
RW
Following error
RW
window
Max torque
RW
Target position
RW
Min position limit
RW
Max position limit
RW
Profile velocity
RW
Profile acceleration
RW
Profile deceleration
RW
Motion profile type
RW
Statusword
RO
Position demand value
RO
Position actual value
RO
Velocity actual value
RO
Torque actual value
RO
Following error actual
RO
value
Control effort
RO
Position demand
RO
internal value
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Position actual value (6064 hex)
Following error actual value (60F4 hex)
Velocity actual value (606C hex)
Control
function
Torque actual value (6077 hex)
(=Torque demand)
Control effort (60FA hex)
Size
Unit
U16
INT8
U32
Command
0 to 134,217,728,
units
or 4,294,967,295
U16
0.1%
INT32
Command
units
to 2,147,483,647
INT32
Command
units
to 1,073,741,823
INT32
Command
units
to 1,073,741,823
U32
Command
units/s
U32
Command
1 to 655,350,000
2
units/s
U32
Command
1 to 655,350,000
2
units/s
INT16
U16
INT32
Command
units
to 2,147,483,647
INT32
Command
units
to 2,147,483,647
INT32
Command
units/s
to 2,147,483,647
INT16
0.1%
INT32
Command
units
to 2,147,483,647
INT32
Command
units/s
INT32
External
encoder units
to 2,147,483,647
Default
Setting range
setting
0 to FFFF hex
0000 hex
0 to 10
0
100000
0 to 5000
5000
2,147,483,648
0000 hex
1,073,741,823
-500000
1,073,741,823
500000
0 to
0000 hex
2,147,483,647
1000000
1000000
1 to 0
0
0 to FFFF hex
0000 hex
2,147,483,648
0000 hex
2,147,483,648
0000 hex
2,147,483,648
0000 hex
-5,000 to 5,000
0000 hex
2,147,483,648
0000 hex
1,073,741,823
0000 hex
to 1073741823
2,147,483,648
0000 hex

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents