Omron R88D-KN series User Manual page 533

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Event name
Interface Input Duplicate Allocation Error 2
Meaning
There is a duplicate setting in the input signal (IN5, IN6, IN7, and IN8) function allocations.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
There is a duplicate setting in the
input signal (IN5, IN6, IN7, and IN8)
function allocations.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F133 is given as the AlarmCode (4001 hex).
Remarks
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Allocate the functions to the
connector pins so that each function
is allocated only once.
Event code
38460000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Allocate the functions to the
connector pins so that each function
is allocated only once.
Appendicies
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
System
A-133