Event name
Other Errors
Meaning
The Servo Drive malfunctioned, or an error occurred in the Servo Drive.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The control circuit malfunctioned
temporarily due to excess noise.
The self-diagnosis function of the
Servo Drive detected an error in the
Servo Drive.
Attached
None
information
Precautions/
"99" is displayed on the Servo Drive front panel and F*99 is given as the AlarmCode (4001 hex)
Remarks
Event name
Safety Input Error
Meaning
At least one of the input photocouplers for safety inputs 1 and 2 turned OFF.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The cable is disconnected or broken.
Attached
None
information
Precautions/
"30" is displayed on the Servo Drive front panel and F030 is given as the AlarmCode (4001 hex).
Remarks
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
---
Remedy
Cycle the power supply of the Servo
Drive.
If the error persists even after taking
the countermeasures above, replace
the Servo Drive.
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Reconnect the input wiring for safety
inputs 1 and 2. If the cable is broken,
replace it.
Event code
04B20000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherCAT LINK/ACT
---
Name
---
Prevention
Take noise countermeasures.
None
Event code
080B0000 hex
Slave
Detection
timing
Error reset (after
Log category
resetting slave
errors)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Reconnect the input wiring for safety
inputs 1 and 2.