9 Servo Parameter Objects
Force Command Filter Time Constant 2
3109 hex
Setting range
0 to 2500
Size
2 bytes (INT16)
*1 The default setting is 126 for a Drive with 200 V and 1 kW or greater, or with 400 V.
• Set the second force filter time constant.
• The objects from 3105 to 3109 hex are the gain and time constants to be selected when the Gain
Switching Input Operating Mode Selection (3114 hex) is enabled.
• The gain is switched according to the condition set in the Switching Mode (3115 hex, 3120 hex, and
3124 hex).
• If the mechanical system mass changes greatly or if you want to change the responsiveness
depending on whether the motor is moving or being stopped, you can achieve the appropriate control
by setting the gains and time constants beforehand for each of these conditions, and switching them
according to the condition.
• This object is automatically changed by executing realtime autotuning function. To set it manually, set
the Realtime Autotuning Mode Selection (3002 hex) to "0."
Speed Feed-forward Gain
3110 hex
Setting range
0 to 1000
Size
2 bytes (INT16)
• Set the feed-forward gain.
• Increasing the set value decreases the position error and increases the responsiveness.
Overshooting, however, will occur more easily.
Refer to 11-10 Feed-forward Function on page 11-30.
Speed Feed-forward Command Filter
3111 hex
Setting range
0 to 6400
Size
2 bytes (INT16)
• Set the time constant for the first-order lag filter inserted into the feed-forward.
• Setting the filter may improve operation if speed overshooting occurs or the noise during operation is
large when the feed-forward is set high.
Refer to 11-10 Feed-forward Function on page 11-30.
Force Feed-forward Gain
3112 hex
Setting range
0 to 1000
Size
2 bytes (INT16)
• Set the feed-forward gain in force control. Increasing the set value decreases the position error and
increases the responsiveness. Overshooting, however, will occur more easily.
Refer to 11-10 Feed-forward Function on page 11-30.
9-10
Unit
0.01 ms
Default setting
Access
Unit
0.1%
Default setting
Access
Unit
0.01 ms
Default setting
Access
Unit
0.1%
Default setting
Access
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
*1
84
Data attribute
RW
PDO map
300
Data attribute
RW
PDO map
50
Data attribute
RW
PDO map
0
Data attribute
RW
PDO map
All
B
Not possible.
csp pp hm
B
Not possible.
csp pp hm
B
Not possible.
csp
pp hm
csv
B
Not possible.