Regeneration
absorption
*1
capacity
Model
Resistance
*2
value
Connection
method
Regeneration
absorption
*1
capacity
Model
Resistance
*2
value
Connection
method
*1 Select a combination that has an absorption capacity greater than the average regeneration power (Pr).
*2 Do not use a combination with resistance values lower than the allowable minimum regeneration resistance of
each drive. For information on the allowable minimum regeneration resistance, refer to 4-4-2 Servo Drive Regenera-
tion Absorption Capacity on page 4-53.
Precautions for Safe Use
Surface temperatures on regeneration resistance can reach 200C.
Do not place objects that tend to catch fire nearby. To prevent people from touching them, install
a cover that enables heat dissipation.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
140 W
R88A-RR22047S
R88A-RR22047S1
23.5 
R
R
R
R
180 W
R88A-RR50020S
20 
R
280 W
R88A-RR22047S
R88A-RR22047S1
47 
R
R
R
R
360 W
R88A-RR50020S
10 
R
R
R
R
4 System Design
560 W
R88A-RR22047S
R88A-RR22047S1
23.5 
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
1440 W
R88A-RR50020S
10 
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R