Omron R88D-KN series User Manual page 264

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

9 Servo Parameter Objects
Regeneration Resistor Selection
3016 hex
0 to 3
Setting range
Size
2 bytes (INT16)
*1 The default setting is 0 for a Drive with 100 V and 400 W, with 200 V and 750 W or greater, or with 400 V.
• The setting is different whether the Regeneration Resistor built in the Drive is directly used, or it is
removed and replaced by an External Regeneration Resistor.
• An external regeneration resistor can be connected as required to the external regeneration resistor
connection terminal.
Explanation of Settings
Set
Regeneration
value
Resistor used
0
Built-in Resistor
1
External Resistor
2
External Resistor
3
Precautions for Correct Use
Precautions for Correct Use
• Do not touch the External Regeneration Resistor. A burn injury may result.
• Always provide a temperature fuse or other protective measure when using an External
Regeneration Resistor. Regardless of whether the regeneration overload error is enabled or
disabled, the Regeneration Resistor can generate heat and may cause burning.
• To use the Built-in Regeneration Resistor, always set this object to 0.
External Regeneration Resistor Setting
3017 hex
Setting range
0 to 4
Size
2 bytes (INT16)
• Select the method to calculate the regeneration resistance load ratio, when the External Resistor is
selected in the Regeneration Resistor Selection.
Explanation of Settings
Set value
0
Regeneration load ratio is 100% when operating rate of the External Regeneration Resistor is
10%.
1
Reserved
2
Reserved
3
Reserved
4
Reserved
9-6
Unit
Access
The regeneration processing circuit operates and the Regeneration Overload
Error (Error No. 18.0) are enabled according to the Built-in Resistor. The duty
ratio is approx. 1%.
The regeneration processing circuit operates, and Regeneration Overload Error
(Error No. 18.0) cause a trip when the operating rate of the Regeneration
Resistor exceeds 10%.
The regeneration processing circuit operates, but Regeneration Overload Error
(Error No. 18.0) do not occur.
None
The regeneration processing circuit and Regeneration Overload Error (Error No.
18.0) do not operate, and all regenerative energy is processed by the built-in
capacitor.
Unit
Access
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Default setting
RW
Description
Default setting
RW
Description
*1
Data attribute
3
PDO map
Not possible.
0
Data attribute
PDO map
Not possible.
All
C
All
C