Omron R88D-KN series User Manual page 307

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Warning Mask Setting
3638 hex
32768 to
Setting range
32767
Size
2 bytes (INT16)
• Set the warning detection mask setting.
• If you set the corresponding bit to 1, the corresponding warning detection is disabled.
Refer to the General Warnings on page 12-5.
Explanation of Settings
Warning
Bit
number
0 to 1
-
2
A7
3
-
4
-
5
A1
6
A3
7
A0
8
A8
9
A6
10
A9
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Unit
Access
Warning name
Reserved (Do not use.)
Life Expectancy Warning
Reserved (Do not use.)
Reserved (Do not use.)
Excessive Regeneration Warning
Fan Warning
Overload Warning
External Encoder Error Warning
Vibration Detection Warning
External Encoder
Communications Warning
9 Servo Parameter Objects
Default
4
setting
RW
PDO map
Warning condition
The life expectancy of the capacitor or the fan is
shorter than the specified value.
The regeneration load ratio is 85% or more of the
level.
The fan stops for 1 second.
The load ratio is 85% or more of the protection level.
The external encoder detects a warning.
Vibration is detected.
The external encoder has more communications
errors in series than the specified value.
All
Data
C
attribute
Not possible.
9
9-49

Hide quick links: