loop-protection action-delay-time

Overview
Use this command to sets the loop protection action delay time for an interface to
specified values in seconds. The action delay time specifies the waiting period for
the action.
Use the no variant of this command to reset the loop protection action delay time
for an interface to default.
loop-protection action-delay-time <0-86400>
Syntax
no loop-protection action
Default
Action delay timer is disabled by default.
Mode
Interface Configuration
Example
To configure a loop protection action delay time of 10 seconds on port 1.0.4, use
the commands:
awplus#
awplus(config)#
awplus(config-if)#
Related
show loop-protection
Commands
613-50157-01 Rev C
-
TIME
Parameter
Description
<0-86400>
Time in seconds; 0 means action delay timer is disabled.
configure terminal
interface port1.0.4
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.7-0.x
loop-protection action-delay-time 10