Chapter 10
Vpc Commands
S e n d c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
id
--
20
This example also shows how to display brief information about the vPCs. In this example, the port
channel failed the consistency check, and the device displays the reason for the failure:
switch(config)# show vpc brief
Legend:
vPC domain id
Peer status
vPC keep-alive status
Configuration consistency status: failed
Configuration consistency reason: vPC type-1 configuration incompatible - STP interface
port type inconsistent
vPC role
Number of vPC configured
vPC Peer-link status
---------------------------------------------------------------------
id
--
1
vPC status
----------------------------------------------------------------------
id
--
20
This example also shows how to display information about the tracked objects in the vPCs:
switch(config)# show vpc brief
Legend:
vPC domain id
Peer status
vPC keep-alive status
Configuration consistency status: success
vPC role
Number of vPC configured
Track object
vPC Peer-link status
---------------------------------------------------------------------
id
--
1
OL-16599-01
Port
Status Consistency Reason
----
------ ----------- -------------------------- ------------
Po20
up
success
(*) - local vpc is down, forwarding via vPC peer-link
Port
Status Active vlans
----
------ --------------------------------------------------
Po10
up
1-100
Port
Status Consistency Reason
----
------ ----------- -------------------------- ------------
Po20
up
failed
(*) - local vpc is down, forwarding via vPC peer-link
Port
Status Active vlans
----
------ --------------------------------------------------
Po10
up
1-100
success
: 10
: peer adjacency formed ok
: peer is alive
: secondary
: 1
vPC type-1 configuration
incompatible - STP
interface port type
inconsistent
: 1
: peer adjacency formed ok
: peer is alive
: secondary
: 3
: 12
Cisco Nexus 5000 Series Command Reference
show vpc brief
Active vlans
1-100
Active vlans
-