Vsan Database - Cisco AP775A - Nexus Converged Network Switch 5010 Command Reference Manual

Cisco nexus 5000 series command reference, release 4.1(3)n1(1) (ol-16599-01, august 2009)
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

vsan database

S e n d c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
vsan database
To create multiple fabrics sharing the same physical infrastructure, assign ports to VSANs, turn on or
off interop mode, load balance either per originator exchange or by source-destination ID, and enter
VSAN database mode, use the vsan database command. To remove a configuration, use the no
command in VSAN database mode.
Syntax Description
vsan vsan-id
interface fc slot/port
san-port-channel
portchannel-number.
subinterface-number
vfc vfc-id
interop
mode
loadbalancing
src-dst-id
src-dst-ox-id
name name
suspend
Command Default
None
Cisco Nexus 5000 Series Command Reference
8-140
vsan database
vsan vsan-id
[interface {fc slot/port | san-port-channel port | vfc vfc-id} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}] | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
vsan database
no vsan vsan-id
[interface {fc slot/port | san-port-channel port | vfc vfc-id} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}] | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
Specifies the VSAN ID. The range is 1 to 4093.
(Optional) Specifies the Fibre Channel interface by slot and port number
on the switch.
Configures the SAN port channel interface specified by the SAN port
channel number followed by a dot (.) indicator and the subinterface
number.
Specifies the virtual Fibre Channel interface.
Turns on interoperability mode.
Specifies the interop mode. The range is 1 to 4.
Configures load-balancing scheme.
Sets src-id/dst-id for load-balancing.
Sets ox-id/src-id/dst-id for load-balancing (default).
Assigns a name to the VSAN. Maximum length is 32 characters.
Suspends the VSAN.
Chapter 8
Fibre Channel Commands
OL-16599-01

Advertisement

Table of Contents
loading

Table of Contents