Chapter 8
Fibre Channel Commands
S e n d c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m

fspf passive

To disable the FSPF protocol for selected interfaces, use the fspf passive command. To revert to the
default state, use the no form of the command.
Syntax Description
vsan vsan-id
Command Default
FSPF is enabled.
Command Modes
Interface configuration mode
Command History
Release
4.0(0)N1(1a)
Usage Guidelines
This command is not applicable to virtual Fibre Channel interfaces.
By default, FSPF is enabled on all E ports and TE ports. FSPF can be disabled by setting the interface as
passive using the fspf passive command. FSPF must be enabled on the ports at both ends of the ISL for
the protocol to operate correctly.
Examples
The following example disables the FSPF protocol for the selected interface on VSAN 1:
switch(config)# interface fc 2/1
switch(config-if)# fspf passive vsan 1
Related Commands
Command
show fspf interface
show interface fc
OL-16599-01
fspf passive vsan vsan-id
no fspf passive vsan vsan-id
Specifies a VSAN ID. The range is 1 to 4093.
Modification
This command was introduced.
Description
Displays information for each selected interface.
Displays an interface configuration for a specified FCIP interface.
Cisco Nexus 5000 Series Command Reference