Docking Interlock Open - Xerox DocuColor 2240 Service Manual

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

12-305 Docking Interlock Open

The Docking Interlock is open.
Procedure
Block the Docking Interlock Sensor with a sheet of paper
Y
N
+5 VDC is measured between the Docking Interlock Sensor P/J866-1 and -3
2).
Y
N
Disconnect Finisher PWB P/J850. +5 VDC is measured between Finisher PWB
P850-B10 and -B12.
Y
N
Replace the Finisher PWB
Repair the open circuit between Finisher PWB J850-B10 and -B12 and Docking
Interlock Sensor J866-1 and -3.
+5 VDC is measured between Finisher PWB P/J850-B11 and ground.
Y
N
Replace the Finisher PWB
(PL
+5 VDC is measure between Docking Interlock Sensor P/J866-2 and ground.
Y
N
Check the wire between the Docking Interlock Sensor P/J866-2 and the Finisher
PWB P/J850-A2 for an open circuit or poor contact.
Replace the Docking Interlock Sensor
Mismatching between the Actuator and the Docking Interlock Sensor. Check the Sensor for
improper installation, the Actuator for breakage and bending, and the Finisher and the Main
Processor for the docking failure.
Status Indicator RAPs
12-305
(Figure
1). 012-305 is cleared.
(PL
17.13)
(Figure
3).
17.13)
(PL
17.13).
Top Cover
Interlock
Switch
(Figure
Front Door
Interlock
Switch
Figure 2 12-305 RAP Circuit Diagram - Docking Interlock Sensor
09/03
2-280
Figure 1 Component Location
DC 3535/2240/1632, WC M24
Docking
Interlock
Sensor
(rear)
Initial issue