Door Open Rap; Fuser Door Open Rap - Xerox phaser 3635 Service Manual

Hide thumbs Also See for phaser 3635:
Table of Contents

Advertisement

01-100 Door Open RAP

01-100 The machine has detected that the front door is open. When the front door is open
there is no +24V supply to the motors or the HVPS.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Refer to Wiring Diagram 2. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Check that the interlock switch actuator on the front cover assembly, PL 28.10 Item 7 is
not missing or damaged. If necessary, install a new front cover assembly.
3.
Check that the front cover assembly closes correctly.
4.
If necessary, install a new HVPS, PL 1.10 Item 3.
NOTE: The front door interlock switch is mounted on the HVPS.
Draft 4
Phaser 3635MFP

01-110 Fuser Door Open RAP

01-110 The machine has detected that the fuser door is open. When the front door is open
there is no +24V supply to the motors or the HVPS.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Refer to Wiring Diagram 2. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Open the rear door, then the fuser door, PL 10.12 Item 19.
3.
Check that the interlock switch actuator on the fuser door, PL 10.12 Item 19 is not missing
or damaged. If necessary, install a new fuser door.
4.
Check that the fuser door assembly closes correctly.
5.
If necessary, install a new HVPS, PL 1.10 Item 3.
NOTE: The fuser door interlock switch is mounted on the HVPS.
2-3
WARNING
Status Indicator RAPs
01-100, 01-110

Advertisement

Table of Contents
loading