show dot1x

Overview
This command shows authentication information for dot1x (802.1X) port
authentication.
If you specify the optional all parameter then this command also displays all
authentication information for each port available on the switch.
For information on filtering and saving command output, see the
with AlliedWare_Plus" Feature Overview and Configuration
show dot1x [all]
Syntax
Mode
Privileged Exec
awplus#
Example
Table 1: Example output from the show dot1x all command
awplus# show dot1x all
802.1X Port-Based Authentication Enabled
RADIUS server address: 150.87.18.89:1812
Next radius message id: 5
RADIUS client address: not configured
Authentication info for interface port1.0.6
portEnabled: true - portControl: Auto
portStatus: Authorized
reAuthenticate: disabled
reAuthPeriod: 3600
PAE: quietPeriod: 60 - maxReauthReq: 2 - txPeriod: 30
PAE: connectTimeout: 30
BE: suppTimeout: 30 - serverTimeout: 30
CD: adminControlledDirections: in
KT: keyTxEnabled: false
critical: disabled
guestVlan: disabled
dynamicVlanCreation: single-dynamic-vlan
assignFailActionRule: deny
hostMode: multi-supplicant
maxSupplicant:
1024
C613-50170-01 Rev B
Parameter
Description
all
Displays all authentication information for each port available on the
switch.
show dot1x all
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
"Getting Started
Guide.
1697

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents