Physical-Ring - Allied Telesis x510-28GTX Command Reference Manual

Stackable gigabit edge switches x510 series
Table of Contents

Advertisement

G.8032 E
R
P
THERNET
ING
ROTECTION
-
PHYSICAL
RING

physical-ring

Overview
Use this command to specify which G.8032 physical ring instance is to be used by
this G.8032 Ethernet Ring Protection (ERP) instance.
physical-ring <physical-ring-name>
Syntax
Mode
G8032 Configure Switch
Usage
A G.8032 ERP instance in general has two ring ports, unless it is at the end of a
sub-ring in which case it has only one ring port. Ring port(s) are specified using a
G.8032 physical ring instance.
This command can only be accepted when the ERP instance is disabled.
Example
To configure an ERP instance named "blue" to use a physical ring instance named
"red", use the following commands:
awplus(config)#
awplus(g8032-config-switch)#
Related
g8032 erp-instance
Commands
g8032 physical-ring
show g8032 erp-instance
Command
Version 5.4.7-0.1: command added
changes
C613-50170-01 Rev B
S
C
WITCHING
OMMANDS
Parameter
<physical-ring-name>
g8032 erp-instance blue
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
Description
The name of the physical ring instance.
physical-ring red