Level (G.8032) - Allied Telesis x510-28GTX Command Reference Manual

Stackable gigabit edge switches x510 series
Table of Contents

Advertisement

G.8032 E
R
P
THERNET
ING
ROTECTION
(G.8032)
LEVEL

level (G.8032)

Overview
Use this command to configure the level for Ring-Automatic Protection Switching
(R-APS) messages.
level <0-7>
Syntax
Default
The default level is 0.
Mode
G8032 Configure Switch
Usage
Inside the R-APS messages is the Level field. The G.8032 Ethernet Ring Protection
(ERP) instance will use the configured level for sending R-APS messages, and is the
level that the instance expects to receive. If the node receives an R-APS message
with the improper level then the message will not be processed.
The ERP instance must be disabled to change the level, otherwise the setting is
denied.
Example
To set the R-APS message level field for an ERP instance named "blue" to 3, use the
following commands:
awplus(config)#
awplus(g8032-config-switch)#
Related
g8032 erp-instance
Commands
show g8032 erp-instance
Command
Version 5.4.7-0.1: command added
changes
C613-50170-01 Rev B
S
C
WITCHING
OMMANDS
Parameter
Description
<0-7>
The level used by the G.8032 ERP instance.
g8032 erp-instance blue
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
level 3
2193