14.3.6.18 set pwa quietperiod

Use this command to set the amount of time a port will remain in the held state after a user
unsuccessfully attempts to log on to the network.
set pwa quietperiod time [port-string]
Syntax Description
time
port-string
Command Type
Switch command.
Command Defaults
If port-string is not specified, quiet period will be set for all ports.
Command Mode
Read-Write.
Example
This example shows how to set the PWA quiet period to 30 seconds for ports fe.1.5-7:
Matrix(rw)->set pwa quietperiod 30 fe.1.5-7
Configuring Port Web Authentication (PWA)
Specifies quiet time in seconds.
(Optional) Sets the quiet period for specific port(s). For a
detailed description of possible port-string values, refer
to
Section
4.1.1.
Matrix NSA Series Configuration Guide
Security Configuration Command Set