Channel to Channel Phase Match
Using different filter selections (Bessel IIR/FIR/etc.) or different filter bandwidths will lead to phase mismatches between channels.
Bessel IIR (Fc @ -3 dB), 20 kHz Filter frequency; 10 kHz sine wave
GN814 Channels within mainframe
FIR (Fc@ -0.1dB) and FIR (Fc @ -3 dB), 50 kHz Filter frequency; 10 kHz sine wave
GN814 Channels within mainframe
GN814 Channels across mainframes
On-board Memory
Per card
Organization
Memory diagnostics
Storage sample size
Digital Events/Timer/Counter
Digital event inputs
Digital event outputs
Timer/Counter
464
Channels on card
0.4 deg (0.1 µs)
0.4 deg (0.1 µs)
Channels on card
0.4 deg (0.1 µs)
0.4 deg (0.1 µs)
Defined by synchronization method used (None, IRIG, GPS, Master/Slave)
128 MB (64 MS)
Automatic distribution amongst enabled channels
Automatic memory test when system is powered and not recording
16 bits, 2 bytes/sample
Not supported
Not supported
Not supported
GEN5i