Sign In
Upload
Manuals
Brands
HBM Manuals
Measuring Instruments
C9C
HBM C9C Manuals
Manuals and User Guides for HBM C9C. We have
2
HBM C9C manuals available for free PDF download: Mounting Instructions
HBM C9C Mounting Instructions (140 pages)
Brand:
HBM
| Category:
Measuring Instruments
| Size: 0.57 MB
Table of Contents
English
4
Table of Contents
4
Safety Instructions
6
Scope of Supply, Accessories and Equipment Variants
11
General Application Instructions
13
Structure and Mode of Operation
14
Transducer
14
Strain Gage Covering Agent
14
Inline Amplifier
14
Conditions on Site
16
Ambient Temperature
16
Moisture and Corrosion Protection
16
Deposits
17
General Installation Guidelines
18
Mechanical Installation
18
Important Precautions During Installation
18
Electrical Connection
22
Connection to Measuring Amplifier Without Permanently Connected
22
General Information and Connection
22
Cable Extension and Cable Shortening
23
EMC Protection
23
TEDS Transducer Identification
24
Electrical Connection of Measuring Amplifier with Amplifier Module
25
General Information
25
Connecting the Device
25
Operating the Inline Amplifier/Zeroing the Measurement Chain
26
Deutsch
38
Sicherheitshinweise
40
Lieferumfang, Zubehör und Ausstattungsvarianten
45
Allgemeine Anwendungshinweise
47
Aufbau und Wirkungsweise
48
Aufnehmer
48
Dmsabdeckung
48
Inline Verstärker
48
Bedingungen am Einsatzort
50
Feuchtigkeits und Korrosionsschutz
50
Umgebungstemperatur
50
Ablagerungen
51
Allgemeine Einbaurichtlinien
52
Mechanischer Einbau
52
Wichtige Vorkehrungen Beim Einbau
52
Allgemeine Hinweise und Verschaltung
56
Anschluss an Messverstärker ohne Fest Angeschlossenes
56
Elektrischer Anschluss
56
Emvschutz
57
Kabelverlängerung und Kabelkürzung
57
Aufnehmer - Identifikation TEDS
58
Allgemeine Hinweise
59
Anschluss des Gerätes
59
Elektrischer Anschluss Messverstärker mit Verstärkermodul
59
Betrieb des Inline-Verstärkers / Nullsetzen der Messkette
60
Français
72
Consignes de Sécurité
74
Matériel Livré, Accessoires Et Variantes D'équipement
79
Consignes Générales D'utilisation
81
Amplificateur de Mesure en Ligne
82
Capteur
82
Conception Et Principe de Fonctionnement
82
Recouvrement des Jauges
82
Conditions Sur Site
84
Protection Contre L'humidité Et la Corrosion
84
Température Ambiante
84
Dépôts
85
Directives de Montage Générales
86
Montage Mécanique
86
Précautions Importantes Lors du Montage
86
Raccordement À un Amplificateur de Mesure Sans Module Amplificateur Fixe
90
Raccordement Électrique
90
Remarques Générales Et Branchement
90
Protection CEM
91
Rallonge Et Raccourcissement de Câbles
91
Capteur - Identification TEDS
92
Raccordement de L'appareil
93
Raccordement Électrique D'un Amplificateur de Mesure Avec Module Amplificateur
93
Remarques Générales
93
De Mesure
94
Fonctionnement de L'amplificateur en Ligne / Mise À Zéro de la Chaîne
94
Italiano
106
Note Sulla Sicurezza
108
Contenuto Della Fornitura, Zubehör E Varianti DI Dotazione
114
Note Generali Sull'impiego
115
Amplificatore Inline
116
Materiale DI Rivestimento Degli er
116
Struttura E Modo Operativo
116
Trasduttore
116
Condizioni Nel Luogo D'impiego
118
Protezione da Umidità E Corrosione
118
Temperatura Ambientale
118
Depositi
119
Direttive Generali Per Il Montaggio
120
Misure Importanti Per Il Montaggio
120
Montaggio Meccanico
120
Avvisi Generali E Collegamento
124
Collegamento All'amplificatore DI Misura Senza Modulo Amplificatore Collegato in Modo Fisso
124
Collegamento Elettrico
124
Cavo DI Prolungamento E Accorciamento del Cavo
125
Protezione EMC
125
Identificazione Trasduttore TEDS
126
Avvisi Generali
127
Collegamento Della Custodia
127
Collegamento Elettrico Amplificatore DI Misura con Modulo Amplificatore
127
Uso Dell'amplificatore Inline/Reset Della Catena DI Misura
128
Advertisement
HBM C9C Mounting Instructions (120 pages)
Brand:
HBM
| Category:
Security Sensors
| Size: 0.43 MB
Table of Contents
English
4
Table of Contents
4
Safety Instructions
5
Scope of Supply and Equipment Variants
11
General Application Instructions
13
Structure and Mode of Operation
14
Transducer
14
SG Covering Agent
14
Conditions on Site
16
Ambient Temperature
16
Moisture and Corrosion Protection
16
Deposits
17
Mechanical Installation
18
Important Precautions During Installation
18
General Installation Guidelines
19
Electrical Connection
22
Connection to an Amplifier
22
Cable Extension and Cable Shortening
23
EMC Protection
24
TEDS Transducer Identification
25
Dimensions
27
C9C Specifications
30
Versions and Ordering Numbers
30
Deutsch
32
Sicherheitshinweise
33
Lieferumfang und Ausstattungsvarianten
39
Allgemeine Anwendungshinweise
41
Aufbau und Wirkungsweise
42
Aufnehmer
42
Dmsabdeckung
42
Bedingungen am Einsatzort
44
Feuchtigkeits und Korrosionsschutz
44
Umgebungstemperatur
44
Ablagerungen
45
Mechanischer Einbau
46
Wichtige Vorkehrungen Beim Einbau
46
Allgemeine Einbaurichtlinien
47
Anschluss an einen Messverstärker
51
Elektrischer Anschluss
51
Kabelverlängerung und Kabelkürzung
52
Emvschutz
53
Aufnehmer - Identifikation TEDS
54
Abmessungen
56
Ausführungen und Bestellnummern
59
Technische Daten C9C
59
Français
62
Consignes de Sécurité
63
Étendue de la Livraison et Variantes D'équipement
69
Consignes Générales D'utilisation
71
Capteur
72
Recouvrement des Jauges
72
Structure et Principe de Fonctionnement
72
Conditions Sur Site
74
Protection Contre L'humidité et la Corrosion
74
Température Ambiante
74
Dépôts
75
Montage Mécanique
76
Précautions Importantes Lors du Montage
76
Directives de Montage Générales
77
Raccordement à un Amplificateur de Mesure
81
Raccordement Électrique
81
Rallonge et Raccourcissement de Câbles
82
Protection CEM
83
Capteur - Identification TEDS
84
Dimensions
86
Caractéristiques Techniques C9C
89
Versions et Numéros de Commande
89
Italiano
92
Note Sulla Sicurezza
93
Dotazione DI Fornitura E Varianti
99
Note Generali Sull'impiego
101
Protezione Degli er
102
Struttura E Modo DI Funzionamento
102
Trasduttore
102
Campo Della Temperatura Ambiente
104
Condizioni del Luogo DI Installazione
104
Protezione Dall'umidità E Dalla Corrosione
104
Sedimenti
105
Installazione Meccanica
106
Precauzioni Importanti Durante Il Montaggio
106
Direttive Generali Per Il Montaggio
107
Collegamento All'amplificatore DI Misura
111
Collegamento Elettrico
111
Allungamento Ed Accorciamento del Cavo
112
Compatibilità EMC
113
Identificazione Trasduttore TEDS
114
Dimensioni
116
Dati Tecnici C9C
119
Versioni E Numeri DI Catalogo
119
Advertisement
Related Products
HBM SomatXR CX23-R
HBM CMA Series
HBM CMA1
HBM CMA2
HBM CMA20
HBM CMA158
HBM CMA210
HBM CMA482
HBM CMA5000/2
HBM CFT
HBM Categories
Transducer
Measuring Instruments
Accessories
Amplifier
Industrial Equipment
More HBM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL