Triggering
Analog channel trigger modes
Analog channel qualifier modes
Trigger holdoff
Interval timer
Event counter
Alarm Output
Selection per Card
Alarm modes
Alarm levels
Alarm output
Alarm output delay
Real-Time Analysis
®
StatStream
Patent Number : 7,868,886
Acquisition Modes
Single sweep
Multiple sweeps
Slow fast sweep
I2679-4.0 en
Pulse detect/reject
Disable/Detect/Reject selectable. Maximum pulse width 65 535 samples
dY/dT conversion
dY : 16 bit (0.0015 %) for both levels
dT : 1 to 1023 samples. dT setting shared for both levels
Basic
POS or NEG crossing; single level
Dual level
One POS and one NEG crossing; Two individual levels, OR-ed
Window
Arm/trigger and a disarm level; Trigger on peak-level changes in a uni-polar signal
Dual Window
Arm/trigger/disarm per level; Trigger on peak-level changes in a bi-polar signal
Sequential
One arm and one trigger level; eliminate false triggering due to noise or hysteresis
Basic
Above or below level check. Enable/disable trigger with single level
Dual (level)
Outside or within bounds check. Enable/disable trigger with dual level
Disable channel trigger for 1 to 65 535 samples after trigger detected
Maximum holdoff time sample rate dependent
Modes
Less then, trigger when rate is too low
More then, trigger when rate is too high
Between, trigger when rate between lower and upper limit
Not between, trigger when rate is not between lower and upper limit
Interval timers
Start timer and width Timer
Timer value
1 to 65 535 samples
Counted channel trigger events before card trigger is activated
1 to 256 trigger events
User selectable On/Off
Basic or Dual
Basic
Above or below level check
Dual (level)
Outside or within bounds check
Levels
Maximum 2 level detectors
Resolution
16 bit (0.0015 %); for each level
Active during valid alarm condition, output supported through mainframe
515 µs ± 1 µs + maximum 1 sample period using decimal time base
503 µs ± 1 µs + maximum 1 sample period using binary time base
Each channel includes real-time extraction of Maximum, Minimum, Mean, Peak-to-Peak,
Standard Deviation and RMS values
Supports the real-time Live scrolling and scoping waveform displays as well as the real-time
meters during recording
Supports the fast displaying and zooming within extremely large recordings
Supports the fast calculation of statistical channel information
Triggered acquisition to on-board memory without sample rate limitations; for single
transients or intermittent phenomena. No aggregate sample rate limitations.
Triggered acquisition to on-board memory without sample rate limitations; for repetitive
transients or intermittent phenomena. No aggregate sample rate limitations.
Identical to single sweep acquisition with additional support for fast sample rate switches
during the post-trigger segment of the slow rate single sweep settings. No aggregate sample
rate limitations.
GEN5i
339