RM0461
The RTC output on PC13 only is functional in Standby mode. PC14 and PC15 used for LSE
are also functional. Three wakeup pins (WKUPx, x = 1, 2, 3) and the three TAMP tampers
are available.
The sub-GHz radio is functional and PVD can be enabled.
Enter Standby mode
The Standby mode is entered according
Cortex system control register is set (see
In Standby mode, the following features can be selected by programming individual control
bits:
•
Independent watchdog (IWDG): the IWDG is started by writing to its key register or by
hardware option. Once started it cannot be stopped except by a reset. See
Section 28.3: IWDG functional
•
Real-time clock (RTC): this is configured by the RTCEN bit in the Backup domain
control register (RCC_BDCR)
•
Internal RC oscillator (LSI): this is configured by the LSIxON bit in the control/status
register (RCC_CSR).
•
External 32.768 kHz oscillator (LSE): this is configured by the LSEON bit in the Backup
domain control register (RCC_BDCR)
•
Sub-GHz radio activity, as programmed, see
•
PVD detection configured in
Exit Standby mode
The Standby mode is exited according to
the
PWR extended status and status clear register (PWR_EXTSCR)
was in Standby mode. All registers are reset after wakeup from Standby except for
extended status and status clear register
Section
5.4.3, when the SLEEPDEEP bit in the
Table 46
for details).
description.
Section 4: Sub-GHz radio
PWR control register 3
Section
5.4.4. The SBF status flags (CnSBF) in
(PWR_EXTSCR).
RM0461 Rev 5
Power control (PWR)
(SUBGHZ).
(PWR_CR3).
indicate that the MCU
PWR