Default level
2: System level
Parameters
delay: Delay period to send LLDPDUs, in the range 1 to 8192 (in seconds).
Description
Use the lldp timer tx-delay command to set the delay period to send LLDPDUs.
Use the undo lldp timer tx-delay command to restore the default.
By default, the delay period to send LLDPDUs is 2 seconds.
Examples
# Set the delay period to send LLDPDUs to 4 seconds.
<Sysname> system-view
[Sysname] lldp timer tx-delay 4

lldp timer tx-interval

Syntax
lldp timer tx-interval interval
undo lldp timer tx-interval
View
System view
Default level
2: System level
Parameters
interval: Interval to send LLDPDUs, in the range 5 to 32768 (in seconds).
Description
Use the lldp timer tx-interval command to set the interval to send LLDPDUs.
Use the undo lldp timer tx-interval command to restore the default.
By default, the interval to send LLDPDUs is 30 seconds.
To enable local device information to be updated on neighboring devices before being aged out, make
sure the interval to send LLDPDUs is shorter than the TTL of the local device information.
Examples
# Set the interval to send LLDPDUs to 20 seconds.
<Sysname> system-view
[Sysname] lldp timer tx-interval 20