Lldp Hold-Multiplier; Lldp Management-Address-Format String - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

lldp hold-multiplier

Syntax
lldp hold-multiplier value
undo lldp hold-multiplier
View
System view
Default level
2: System level
Parameters
value: TTL multiplier, in the range 2 to 10.
Description
Use the lldp hold-multiplier command to set the TTL multiplier.
Use the undo lldp hold-multiplier command to restore the default.
The TTL multiplier defaults to 4.
You can set the TTL of the local device information by configuring the TTL multiplier.
The TTL of the information about a device is determined by the following expression:
You can set the TTL of the local device information by configuring the TTL multiplier. Note that the TTL
can be up to 65535 seconds. TTLs longer than it will be rounded off to 65535 seconds.
Related commands: lldp timer tx-interval.
Examples
# Set the TTL multiplier to 6.
<Sysname> system-view
[Sysname] lldp hold-multiplier 6

lldp management-address-format string

Syntax
lldp management-address-format string
undo lldp management-address-format
View
Ethernet interface view, port group view
Default Level
2: System level
TTL multiplier × LLDPDU transmit interval