If the
command sets specified date parameters, which
schedule reboot at
represents a data in the future, the switch will be restarted in specified time, with
error not more than 1 minute.
If no specified date parameters are configured, two cases are involved: If the
configured time is after the current time, the switch will be restarted at the time
point of that day; if the configured time is before the current time, the switch will
be restarted at the time point of the next day.
It should be noted that the configured date should not exceed the current date
more than 30 days. In addition, after the command is configured, the system will
prompt you to input confirmation information. Only after the "Y" or the "y" is
entered can the configuration be valid. If there is related configuration before, it
will be covered directly.
After the
command is configured and the system time is
schedule reboot at
adjusted by the
command, the former configured
clock
schedule reboot at
parameter will go invalid.
For the related command, see
reboot, schedule reboot delay, display
schedule reboot.
Example
Set the switch to be restarted at 22:00 that night (the current time is 15:50).
<SW5500>schedule reboot at 22:00
Reboot scheduled for 22:00:00 UTC 2002/11/18 (in 6 hours and 10
minutes)
Proceed with reboot? [Y/N]:y

schedule reboot delay

Syntax
hhh:mm
mmm
schedule reboot delay {
|
}
undo schedule reboot
View
User view
Parameter
: Waiting time for rebooting a switch, in the format of "hour: minute" The
hhh:mm
hhh ranges from 0 to 720, and the mm ranges from 0 to 59.
: Waiting delay for rebooting a switch, in the format of "absolute minutes" .
mmm
Ranging from 0 to 43200,
Description
Use the
command to enable the timing reboot switch
schedule reboot delay
function and set the waiting time. Use the
command to
undo schedule reboot
disable the timing reboot function.
By default, the timing reboot switch function is disabled.