Symptom Troubleshooting Index

Symptom
Recirculation control
doors do not change
between Fresh and
Recirculate (4-door
with A/T)
Blower, heater controls,
and A/C do not work
The A/C condenser fan
does not run at all (but
radiator fan runs with
the A/C on)
Both fans do not run
with the A/C on (but the
A/C compressor runs
with the A/C on)
The A/C compressor
clutch does not engage
(but both fans run with
the A/C on)
A/C system does not
come on (both fans and
the A/C compressor do
not work); heater is OK
Insufficient heating
TA08AHAG24100000000HBAT01
Diagnostic procedure
Recirculation control motor circuit troubleshooting
(see page 21-40)
HVAC control power and ground circuit
troubleshooting (see page 21-42)
A/C condenser fan circuit troubleshooting
(see page 21-43)
Radiator and A/C condenser fan common circuit
troubleshooting (see page 21-44)
A/C compressor clutch circuit troubleshooting
(see page 21-45)
A/C pressure switch circuit troubleshooting
(see page 21-48)
1.
Check the coolant level (see page 10-6)
2.
Check the radiator cap (see page 10-3)
3.
Check the operation of the air mix control
motor and door (see page 21-52)
4.
Check the coolant temperature
5.
Check the blower motor unit for obstructions
6.
Check for air leaks around the ducts and vents
7.
Check the inlet hose temperature
If it is COLD, check for restrictions in the hose,
a damaged or leaking thermostat, and a
damaged or leaking water pump.
If it is HOT, check for restrictions in the
heater core. Back flush the heater core or
replace the heater core.
Also check for
HVAC DTCs (see page 21-9)
Blown fuse No. 16 (7.5 A) in the
driver's under-dash fuse/relay
box
Cleanliness and tightness of all
terminals
HVAC DTCs (see page 21-9)
Blown fuse No. 16 (7.5 A) in the
driver's under-dash fuse/relay
box
Poor ground at G401
Cleanliness and tightness of all
terminals
HVAC DTCs (see page 21-9)
Blown fuse No. 5 (20 A) in the
under-hood fuse/relay box
Poor ground at G302
Cleanliness and tightness of all
terminals
HVAC DTCs (see page 21-9)
Blown fuse No. 5 (20 A) and
No. 3 (MAIN FAN MTR) (30 A) in
the under-hood fuse/relay box
Cleanliness and tightness of all
terminals
HVAC DTCs (see page 21-9)
Blown fuse No. 20 (7.5 A) in the
under-hood fuse/relay box
Blower motor operation
Cleanliness and tightness of all
terminals
HVAC DTCs (see page 21-9)
Cleanliness and tightness of all
terminals
Damaged cylinder head gasket