8. Check for continuity between the following
terminals of the HVAC control unit 24P connector
and the mode control motor 7P connector.
24P:
No. 7
No. 8
*01
Is there continuity?
YES
−
NO
control unit and the mode control motor.
7P:
No. 1
No. 2
HVAC CONTROL UNIT 24P CONNECTOR
Wire side of female terminals
GRN
WHT
GRY
YEL
MODE CONTROL MOTOR 7P CONNECTOR
Wire side of female terminals
−
Go to step 9.
Repair open in the wire(s) between the HVAC
9. Check for continuity between body ground and the
HVAC control unit 24P connector No. 7 and No. 8
terminals individually.
HVAC CONTROL UNIT 24P CONNECTOR
GRN
WHT
Wire side of female terminals
Is there continuity?
−
YES
Repair short to body ground in the wire(s)
between the HVAC control unit and the mode
control motor.
NO
−
Substitute a known-good HVAC control unit,
and recheck. If the symptom/indication goes away,
replace the original HVAC control unit.