07/11/02 09:40:11 61TA0000_220_0316
The Indicator Drive Circuit Check
When entering the self-diagnostic mode, the following indicators blink:
A/T gear position indicator, ABS indicator, brake system indicator, charging system indicator, cruise control indicator,
cruise main indicator, door indicator, DRL indicator, high beam indicator, immobilizer indicator, lights-on indicator,
low oil pressure indicator, low fuel indicator, low tire pressure indicator, malfunction indicator lamp (MIL),
maintenance required indicator, seat belt indicator, security indicator, side airbag cutoff indicator, SRS indicator,
TPMS indicator, trunk indicator, VSA activation indicator, VSA indicator, and washer fluid level indicator (Canada
models).
Switch Input Check
At the initial stage of the self-diagnostic function, the beeper sounds intermittently. The beeper sounds continuously
when any of the following switch inputs are switched from OFF to ON:
Cruise control master, SET, RESUME, CANCEL switches, SEL/RESET switch, parking brake switch, and VSA OFF
switch.
The Beeper Drive Circuit Check
When entering the self-diagnostic mode, the beeper sounds five times.
The LCD Segment Check
When entering the self-diagnostic mode, all the segments blink five times.
The Gauge Drive Circuit Check
When entering the self-diagnostic mode, the speedometer, the tachometer, the fuel gauge, and the engine coolant
temperature gauge needles sweep from the minimum position to maximum position, then return to the minimum
position.
NOTE:
After the beeper stops sounding and the gauge needles return to the minimum position, pushing the SEL/RESET
switch starts the Beeper Drive Circuit Check (one beep) and the Gauge Drive Circuit Check again.
The check cannot be started again until the gauge needles return to the minimum position.
*02
Self-diagnostic
mode
SEL/RESET
switch
Gauge needles
Beeper
If the needles fail to sweep, or the beeper does not sound, replace the gauge control module.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
5 sec.
The needles sweep from the
minimum position to the
maximum position, then return
to the minimum position.
(cont'd)