7.10 Loop-Back Diagnosis between DLI/DAI and Transmission Equipment
This section explains the procedure of loop-back diagnosis between the DLI/DAI and the transmission
equipment when the DLI/DAI and the DRU/DAU are connected via the transmission equipment.
7.10.1 Procedure for Loop-Back Diagnosis between DLI/DAI and Transmission Equipment
START
PCM Lamp (red) on the DLI/DAI card lights.
Set the corresponding switch of the DLI/DAI card
UP (ON), referring to the table below.
Switch setting for local loop-back check
CIRCUIT CARD NAME
PA-DAIA
PA-DAIJ-A
PA-DAIU
On the DLI/DAI card, various lamps are indicat-
ing as follows.
• LINK (G):
• CRC (R):
• PCM (R):
• FRM (R):
• MFRM (R): Note
• RMT (R):
• BLUE/AIS (R):
A
SWITCH NAME
SW3-1
SW01-1
SW02-1
ON, flashing, or OFF
One or more than one
lamp lights.
Note:
VOL.3-253
CHAPTER 2
TERMINAL-RELATED DEVICES
See if the power supply to the transmission
equipment is normal. Test the connection be-
tween the DLI/DAI and the transmission equip-
ment.
FAULT :
DLI/DAI is faulty
Refer to: DLI/DAI Fault
The MFRM Lamp is not mounted on the PA-