TYPE 1: With DHCP Server (SIP Server's IP Address is Pre-assigned by DHCP Server)
DHCP server is connected to the network. DT700 Series terminal starts up and operates by obtaining
own IP address and subnet mask, IP address (or FQDN) of SIP server, and router (default gateway)
address via the DHCP server.
IP address assignment is not required on the configuration setting of DT700 Series since SIP server's
IP address (or FQDN) is obtained via the DHCP server.
TYPE 2: With DHCP Server (SIP Server's IP Address is Not Assigned by DHCP Server)
DHCP server is connected to the network. DT700 Series terminal starts up and operates by obtaining
own IP address, subnet mask, and router (default gateway) address via the DHCP server.
SIP server's IP address (or FQDN) is the only item necessary to be assigned on the configuration
setting of DT700 Series.
TYPE 3: Without DHCP Server
DHCP is in either of the following status; 1) DHCP server is not connected to the network or 2) the
system is activated in a way that does not use the DHCP server.
It is necessary to assign the below in the DT700 Series' configuration setting:
- DT700 Series terminal's IP address and subnet mask
- SIP server's IP address (or FQDN)
- Router (default gateway) address
[Setting Procedure]
STEP 1: Start up DT700 Series
Turn on the power via PoE feeding or optional AC adapter.
STEP 2: Initialize data
(a) For DT700 Series other than DT710 Series without LCD
1. On the administrator's menu [Config], select "3. Maintenance Settings."
2. On [Maintenance] menu, select "3. Data Clear."
3. On [Data Clear] menu, select "1. Factory Value."
4. On [Factory Value] menu, press the software key "OK."
(b) For DT710 Series without LCD
1. On the terminal, press the following buttons in order: Hold, Transfer, *, *.
2. Make sure that Line Key 1 and 2 are lit green (meaning Factory Value setting mode).
3. Dial "331#".
4. Make sure that Line Key 2 begins flashing.
5. Press Line Key 1.
6. Make sure that Line Key 1 and 2 are lit red (meaning restoring factory defaults).
7. Make sure that Message Waiting Lamp is lit green (if red, some problem occurs).
8. Press Line Key 1 to reboot.
9. Make sure that Line Key 1, 2 and Message Waiting Lamp turn off.
(c) For DT770G without LCD
1. On the terminal, press the following buttons in order: "Mic", "Up", "Mic", "Connect", "Path".
2. Make sure that Line Key 1 and 2 are lit green (meaning Factory Value setting mode).
CHAPTER 4