STEP 8: Connect PCPro (PC) outside your LAN.
Connect a PC with PCPro installed to the SR-MGC(S) through the Ether1 connector on it, so
that you can assign office data to the SR-MGC(S).
If connecting them directly, use a LAN cable (crossover cable); if connecting via a HUB, use LAN cables
Note:
(straight-through cables).
STEP 9: Configure PCPro.
Set data to connect PCPro to the SR-MGC(S).
[PCPro Connection Account Setting]
On the Main Menu, click on System; click on Connection Account Setting; set the following.
Account Name
Connection Type: TCP/IP
TCP/IP Setting
IP Address: 172.16.253.0, a default IP address of an SR-MGC(S)
Port Number: 60000
[PC Setting]
A PC with PCPro needs to have an IP address, subnet mask, and default gateway address set
as follow. After you finish setting, restart the PC.
IP address: 172.16.253.253
Subnet mask: 255.255.0.0
Default gateway address: 172.16.253.0, a default IP address of an SR-MGC(S)
Now you are supposed to be able to login to the SR-MGC(S).
Perform the following to check the connectivity between the PC and SR-MGC(S).
[1]
Open a DOS window; enter
[2]
Make sure that you get replies from the SR-MGC(S) (172.16.253.0).
[3]
Turn on PCPro and login to the SR-MGC(S).
Now you can assign office data.
STEP 10: Set an IP address on the SR-MGC(S).
Set network data including an IP address and health check. For the procedure to set an IP ad-
dress of an SR-MGC(S), see the UNIVERGE SV8500 Data Programming Manual - Business.
; press the Enter key.
ping 172.16.253.0
VOL.2-2139