[PCPro Connection Account Setting]
On the Main Menu, click on System; click on Connection Account Setting; set the following.
Account Name
Connection Type: TCP/IP
TCP/IP Setting
IP Address: 172.16.253.0, a default IP address of an SR-MGC(E)
Port Number: 60000
[PC Setting]
A PC with PCPro needs to have an IP address, subnet mask, and default gateway address set
as follow. After you finish setting, restart the PC.
IP address: 172.16.253.253
Subnet mask: 255.255.0.0
Default gateway address: 172.16.253.0, a default IP address of an SR-MGC(E)
Now you are supposed to be able to login to the SR-MGC(E).
Perform the following to check the connectivity between the PC and SR-MGC(E).
[1]
Open a DOS window; enter
[2]
Make sure that you get replies from the SR-MGC(E) (172.16.253.0).
[3]
Turn on PCPro and login to the SR-MGC(E).
Now you can assign office data.
STEP 9: Set an IP address on the SR-MGC(E).
Set network data including an IP address and health check. For the procedure to set an IP ad-
dress of an SR-MGC(E), see the UNIVERGE SV8500 Data Programming Manual - Business.
STEP 10: Set a time zone on the SR-MGC(E).
Set the same clock and time zone data as an MGC to which the SR-MGC(E) belongs. For the
procedure to set clock and time zone data, see the UNIVERGE SV8500 Data Programming
Manual - Business.
; press the Enter key.
ping 172.16.253.0