Advertisement

Cable Termination and Cross Connection from DRU/DAU (2M AMI) to Dterm/Analog PB TEL
START
Cable running
Cable termination
Check terminal locations on the
DRU/DAU side of the IDF
Cross connection
END
DRU/DAU
DRE card
CHAMP1
CHAMP0
CHAMP
CONNECTOR
(MALE)
CHAMP Connector Cable (25P)
While referring to the figure below, run cables between each
Dterm/Analog PB TEL and its modular block (jack), and be-
tween the Modular Blocks and the IDF.
Protect the cables using cable ducts, etc.
While referring to two figures listed on the following pages, ter-
minate the installed cables to the IDF and the modular blocks.
While referring to Champ Connector Pin Accommodation,
identify the lead names for the CHAMP Connector of DRU/
DAU and the terminal locations of the leads.
While referring to figures Detailed of Dterm/Analog PB TEL
Connection, provide cross connections at the Dterm/Analog PB
TEL side and the DRU/DAU side.
Connection of Dterms/Analog PB TELs
IDF
1-PAIR CABLE
VOL.3-218
CHAPTER 2
TERMINAL-RELATED DEVICES
MODULAR BLOCK
(JACK)
MODULAR
CABLE
Analog PB TEL
or Dterm