To directly enter the setting value:
When P1=TOS is entered:
VS-32(SIP)> SET SIGNALING_QOS TOS 0xC0
Signaling QoS setting succeeded.(0xC0)
When P1=DIFFSERV is entered:
VS-32(SIP)> SET SIGNALING_QOS DIFFSERV 48
Signaling QoS setting succeeded.(0xC0)
When P1=CLEAR is entered to delete the current QoS setting:
VS-32(SIP)> SET SIGNALING_QOS CLEAR
Signaling QoS clearing succeeded.(0x00)
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
The value in ( ) shows the current setting.
Note:
13. Setting IP address, port number, and host name of SIP server:
This command is used for SIP mode only.
VS-32(SIP)> SET SIPSV_IPADDRESS
SIP Server (1-20): 1
IP Address: 10.41.1.150
Port Number: 5060
Is there the Host Name? (Y/N) [N]: y
Host Name: SVR1.nec.com
SIP server setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
VS-32(Dual) [SCA-VS32VA/MG-VS32VA]
P1: Enter TOS to set IP Precedence data value
P2: Enter the setting value [0x02~0xFF]
Result is shown.
P1: Enter DIFFSERV to set Diffserv data value
P2: Enter the DSCP setting value [0~63]
Result is shown.
P1: Enter CLEAR to clear QoS setting
Result is shown.
Enter the SIP server's number [1-20]
Up to 20 SIP servers can be used in one network.
Enter the IP address of SIP server. Note 1
e.g. 10.41.1.150 (default=0.0.0.0)
Enter the port number [1024-65535] (default=5060)
Select whether to use host name [Y/N]
Enter the host name in the full-domain format, within 63-
byte of alphanumerics, ". (period)", and "- (hyphen)".
63. (*This line is displayed when "Y" is selected above.)
Result is shown.
VOL.2-2063