STEP 10: The LCD displays [LLDP Settings] menu. Select "4. Transmit Interval."
[LLDP Settings]
4.Transmit Interval
5.Hold Multiplier
6.Fast Start Count
STEP 11: The LCD displays [Transmit Interval] setting screen.
[Transmit Interval]
5-32768 (second)
BK
Cancel
STEP 12: The LCD displays [LLDP Settings] menu. Select "5. Hold Multiplier."
[LLDP Settings]
4.Transmit Interval
5.Hold Multiplier
6.Fast Start Count
STEP 13: The LCD displays [Hold Multiplier] setting screen.
[Hold Multiplier]
2-10 (multiple)
BK
Cancel
Note: This data is valid when the LLDP mode is enabled.
Note 1: When the value obtained by multiplying [Transmit Interval] value by the [Hold Multiplier] value
exceeds 65535 seconds, the time to live for the LLDP data will be 65535 seconds.
C
Exit
- Set intervals to transmit LLDP packets using digit keys.
- You can set 5-32768 (default interval: 30) seconds.
- Press the software key for "BK" to delete the transmitting interval.
- Press the software key for "OK" when the [Transmit Interval] setting
30
OK
is complete.
Note: This data is valid when the LLDP mode is enabled.
Exit
- Set the time to live for the LLDP data using Digit Keys.
- The time to live will be determined by multiplying
[Transmit Interval] value by the [Hold Multiplier] value. Note 1
- You can set 2-10 (default multiplier: 4) times.
4
OK
- Press the software key for "BK" to delete the [Hold Multiplier] value.
- Press the software key for "OK" when the [Hold Multiplier] settings
is complete.