NEC Univerge sv8500 Manual page 2424

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

STEP 5: Restart the SR S.
[SV7000@SRMGC_SP~]$ sudo shutdown -r now
password:
ACT lamp lights off and the system is automatically restarted. Check to see that ACT lamp lights on,
which indicates the system is operating.
[8] Reset SR T and SR S
First, reset the SR T by turning the PWR switch OFF
follows.
STEP 1: Use telnet to log on to the SR S.
telnet 172.16.253.1
STEP 2: Type "SV7000" twice for login and password, and then make sure the prompt is changed.
login: SV7000
password:
[SV7000@SRMGC_SP~]$
STEP 3: Reset the SR S.
[SV7000@SRMGC_SP~]$ sudo shutdown -r now
password:
[9] PCPro Connection to Network
After the actual network configuration data setting of SR-MGC (such as IP address) has been completed,
connect the PCPro PC to the network.
STEP 1: Change the IP address of PCPro PC corresponding to the actual network.
STEP 2: Restart the PCPro PC.
STEP 3: Connect the PCPro PC to the network with a LAN cable.
[10] SR S Connection to Network
Connect LAN1 port to the actual network by using a LAN cable.
[11] Network Connection Check
Execute ping program from DOS prompt on the PCPro PC to ensure the network connection. Verify the
IP addresses of SR S (ping 172.16.253.1 as an example) from the PCPro PC. When replies are sent back
from SR S, the connection has been established.
Type "sudo shutdown -r now".
Type "SV7000" for password.
ON on the rear side. And then reset the SR S as
Type the IP address of SR S after the telnet command.
Type "SV7000" for login account.
Type "SV7000" for password.
Type "sudo shutdown -r now".
Type "SV7000" for password.
VOL.2-2171
SR-MGC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents