25.10 Remote Version Upgrade
This section describes the procedure to upgrade an SR-MGC(E) program remotely.
The version of an SR-MGC(E) is upgraded remotely by copying the Program File provided in
FTP server to SR-MGC.
Observe the following when performing a Remote Version Upgrade for SR-MGC(E).
Note:
• Remote Version Upgrade of SR-MGC(E) is available only when the versions of the Telephony Server
and SR-MGC(E) are both S6 or later.
• Remote Version Upgrade is only available for Minor Version Upgrade. Major Version Upgrade is not
supported.
Example of Minor Version Upgrade: Upgrading from S6 Issue 1 to S6 Issue 2
Example of Major Version Upgrade: Upgrading from S6 to S7
• Check whether SR-MGC is in Standby Mode when executing a Remote Version Upgrade. If not, switch
SR-MGC from Operation Mode to Standby Mode before executing a Remote Version Upgrade.
• Confirm SIP Server ID before executing a Remote Version Upgrade. SIP Server ID must be reconfig-
ured after executing a Remote Version Upgrade. This reconfiguration is not required for Swtichback.
Maintence PC
3.Transfers the Program File
to each SR-MGC with FTP.
Program File
FTP Server
SR-MGC(E) Remote Version Upgrade Procedure
• For details on hardware information, see Specifications.
• FTP server must be prepared separately from the Telephony Server in order to perform Remote Ver-
sion Upgrade for SR-MGC(E).
Observe the following when preparing a FTP server for Remote Version Upgrade.
Note:
• Import the Program File and the checksum file from the Image folder in the version upgrade DVD
1. Executes a Program Copy
with CMNT command using
PCPro.
VOL.2-2111
2. Program Copy from FTP
Server is directed to
each SR-MGC.
SV8500
SR-MGC
SR-MGC
SR-MGC(E)
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required

Hide quick links: