"13-O": Digital Line Failure
(1)
Meaning
The System Message "13-O" indicates that a fault such as a Frame Loss, Multi-Frame Loss, etc. has occurred
more than 16 times in a one-hour period consecutively during data transfer from the Telephony Server to the
DRU/DAU.
(2)
Related system messages
If the fault of the digital line is restored to normal, the System Message "13-P" is printed out.
(3)
Example of printout
SYSTEM MESSAGE 13-O [MN]
NEC TOKYO
LP00-0-ACT
1: 0701 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
(4)
Message detail data
1: XX 0X
Kind of fault
01: Frame Loss PCM Down
02: Bit Error more than 10
03: Slip Detected
04: Remote Office Alarm Detected
06: Multi-Frame Loss
07: Frame Loss PCM Down (Continuous)
08: Multi-Frame Loss (Continuous)
Accommodated location of detected DLI/DAI card
(Refer to Section 7.9.4)
MG
(5)
Diagnostic from system message
(Refer to System Message "13-N".)
DIGITAL LINE FAILURE
MAY 14 10:30
-4
U
G
CHAPTER 2
MG: Module Group
U:
Unit
G:
Group
VOL.3-245
TERMINAL-RELATED DEVICES