Parameter
hour:minute:second: Current clock. hour, ranging from 0 to 23; minute and second,
ranging from 0 to 59.
year/month/day: Current date. year, ranging from 1997 to 2097, month, ranging from
1 to 12, day, ranging from 1 to 31.
Description
Using the clock command, you can set the current date and clock of the router.
If the router is not yet equipped with a hardware real-time clock, the default clock
value is 0:0:0 1/1/1998 when the system is booted. If the router is equipped with a
real-time clock, the system will read the clock value when booted, and use it for
setting the system time.
When powered off, the routers stop keeping time, so it is necessary to reset the
current date and time for the router in a rigorous application environment.
For related commands, see display clock.
Example
# Set the current date and clock of the router to 0:0:0 Jan. 2nd, 2001.
[3Com] clock 0:0:0 2 1 2001
1.2.2 display base-information
Syntax
display base-information [ page ]
View
All views
Parameter
page: Display in pages.
Description
Using the display base-information command, you can view the basic information
of the system, including the information on version, current configuration, interface,
memory and traffic on the interface. This information helps the network administrator
and technical assistance engineers to learn the overall condition of the router.
Getting Started