undo fr x25 template
View
DLCI view
Parameter
name: Name of X25 template.
Description
Using the fr x25 template command, you can configure the X.25 attributes for X.25
over frame-relay via associating an X.25 template to the DLCI in T1.617 AnnexG mode.
Using the undo fr x25 template command, you can disable the X.25 template and
restore the initial X.25 attributes.
Frame Relay network does not provide reliable transmission. To ensure reliable
transmission, call signals are transmitted on an X.25 VC, as the message
acknowledgement mechanism of X.25 can guarantee reliable transmission. This
command is used to configure the X.25 attributes.
For related commands, see x25 template.
Example
# Specify DLCI 100 to use X.25 template vofr.
[3Com-fr-dlci-100]fr x25 template vofr

5.1.12 lapb max-frame

Syntax
lapb max-frame n1-value
undo lapb max-frame
View
Interface view
Parameter
n1-value: the N1 parameter, ranging 1056 bits to 12804 bits. By default, the n1-value is
12032 bits.
Description
Using the lapb max-frame command, you can configure the LAPB N1parameter.
Using the undo lapb max-frame command, you can restore to the default N1 value.
The N1 value is the maximum number of bits of I frame that the DCE or DTE device
expects to receive from the remote device. This value should be 8 times the MTU plus
Link Layer Protocol