3.2.4 tcp timer syn-timeout

Syntax
tcp timer syn-timeout seconds
View
System view
Parameter
seconds: Value for the TCP synwait timer in seconds, ranging from 2 to 600 seconds.
The default value is 75 seconds.
Description
Using the tcp timer syn-timeout command, you can configure the TCP synwait
timer.
When the synchronous packet is transmitted, the TCP starts the synwait timer. If no
acknowledgment packet is received before the synwait is timed out, then the TCP
connection will be terminated.
This parameter should be configured under the guidance of the technical support
engineer.
For related commands, see tcp timer fin-timeout, tcp window.
Example
# Configure the TCP synwait timer to 75 seconds.
[Quidway] tcp timer syn-timeout 75

3.2.5 tcp window

Syntax
tcp window window-size